CHEMICAL

Nitrogen Generators for the Chemical Industry

NITROBERG® nitrogen generators supply chemical manufacturing sites with inert gas made from their own compressed air, from tank blanketing through to purging whole pipe runs. Purity is adjustable between 97 % and 99.999 %. Whether generating your own beats buying it in by tank or cylinder comes down to quantity, load profile and purity setting. The same three figures take you from your load list to a model.

97 % to 99.999 %Nitrogen purity, set per process
4.1 to 654.9 Nm³/hNitrogen output at 99.9 % across the range
2 to 3 yearsTypical payback versus ongoing bulk liquid nitrogen supply
PED 2014/68/EUConformity assessed, notified body NB 2912
Send Your Load List and Request a Sizing
High N₂ PurityUp to 99.999 % at the point of use
Cut Recurring CostsNo annual price adjustment
Made in GermanyEngineering and manufacturing
Service and Warranty3 years, 5 with a contract

What a Nitrogen Generator Supplies in a Chemical Plant

In a chemical plant, nitrogen keeps oxygen away from everything that would react with it. Four duties account for the consumption. It sits as a nitrogen blanket over solvents and products in tanks and silos, and it inerts reactors running oxygen-sensitive chemistry. It also purges vessels and lines after cleaning, and it gas-frees plant sections before maintenance and entry.

What decides the supply question in chemical manufacturing is volume and duration, not peak purity. Blanketing and purging run continuously and account for most of the consumption. High purity usually hangs on a single process. So the volume decides the plant, and that one process decides the purity.

The gas is made from compressed air. Because the separation happens on a carbon molecular sieve, every purity setting translates directly into compressed air demand. That is the lever the next section is about. The PSA nitrogen generator page sets out the process itself, and the carbon molecular sieve article covers what limits the purity a generator can reach.

Nitrogen Generators for Chemical Industry

Which Process Needs Which Purity, and Which One Drives the Volume

On a site that has grown over the years, the purity figure often sits in the plant documentation untouched, set for the one process that needed it at the time. Everything else has been supplied at that figure ever since. The values below are the ones used in practice, and they are a starting point for checking your own figure against. What binds in the end is your substance data and your risk assessment.

ProcessPurity used in practiceWhat the nitrogen doesDriven by
Blanketing storage and process tanks and silos99.9 %Keeps the headspace out of the ignitable range and the product clear of oxidationVolume
Inerting reactors99.9 % to 99.99 %Holds an inert atmosphere over oxygen-sensitive chemistryPurity
Purging vessels and lines99.9 %Clears residual air and moisture after cleaning and before start-upVolume
Gas-freeing before maintenance and entry99.9 %Displaces ignitable residues before anything is opened or enteredVolume
Solvent recovery99.9 %Carries the process as an inert gas through condensation and recoveryVolume
Catalyst handling99.9 % to 99.99 %Protects against deactivation and self-ignition during transferPurity
Polymer production99.9 % to 99.99 %Inerts reaction, degassing and pellet storagePurity
Pneumatic conveying of powders and bulk solids99.9 %Conveys without letting an explosive atmosphere formVolume

The last column is the one that matters. Five of the eight rows say volume, and that is what separates chemical production from pharmaceutical production. The duties that run all day decide the size of the plant. Purity comes from three processes, and those three can be supplied separately.

How the Purity Setting Decides Your Compressor

Purity is not free. Every cubic metre of nitrogen costs a fixed volume of compressed air, and that ratio, the air factor, climbs steeply above 99.9 %. It is a property of the purity setting, not of the model, so it applies across the whole range.

Purity97 %98 %99 %99.5 %99.9 %99.99 %99.995 %99.999 %
Grade––2.02.53.04.04.55.0
Residual oxygen––10,000 ppm5,000 ppm1,000 ppm100 ppm50 ppm10 ppm
Air factor2.32.32.62.93.44.65.26.4

For 97 % and 98 % the data sheet gives no grade and no residual oxygen figure.

A chemical site drawing 150 Nm³/h continuously for blanketing and purging needs around 510 Nm³/h of compressed air at 99.9 %. Set the same quantity to 99.999 % and it needs around 960 Nm³/h. That is close to twice the compressor and close to twice the electrical load. On top of that the generator moves up several models, because the same machine delivers far less at high purity.

That is a worked example using the published air factors, not a project figure, but the order of magnitude holds for any site. So it pays to supply one demanding process on its own rather than lift the whole site to its purity.

From Load Profile to Nitrogen Generator Size

The size of the generator does not follow from the annual quantity. It follows from the shape of the load. Blanketing draws the same small amount around the clock, a purge cycle draws several times that for a few minutes, a packaging line draws a little without stopping. Work through them in this order and your own list gives you the machine.

1

Record Each Point of Use Separately

Take tank farms, reactors, purge stations, conveying lines and packaging one at a time, each with quantity, duration and timing. A purge cycle is a peak and not a running load. Add up every peak and you arrive at a model that normal operation never uses.

2

Set the Purity per Process

Check the highest requirement on your list against the table above. Then use the air factor to work out what it costs if it applies to the whole site. A second, smaller supply for that one process is often the cheaper answer.

3

Cover Purge Peaks With Buffer Volume, Not a Bigger Generator

A peak that lasts minutes is absorbed by the nitrogen vessel, not by the next model up. Across the range the nitrogen vessels run from 90 l to 6,000 l and the air receivers from 90 l to 10,000 l. What you can actually use is the volume held between storage pressure and process pressure.

4

Check the Compressed Air, Quantity and Quality

Demand times air factor gives the compressed air you need, and that figure has to be set against the spare capacity of your station before a model is fixed. Assume the unfavourable case while you do it: an additional continuous draw of the order used in the worked example above regularly exceeds the spare capacity of a station that has grown over the years, and then extending the compressed air side is part of the investment rather than a minor item. For a first assessment, the delivered volume from your compressors’ rating plates and the actual load from the control system are enough. Chemical sites add a question others do not: where does the compressor take its air from? Solvent vapours in the intake add load to the air treatment. Oil carried over from the compressor and residual moisture both cut short how long the carbon molecular sieve lasts. Floor space, ventilation and waste heat in the compressor room come into it as well.

You Get Back a Model, a Compressed Air Figure and a Buffer Volume

One line per point of use is enough: quantity, duration and purity. Our application engineers work the sizing through and come back with a proposal.

Explosion Protection and the Operator’s Duties

In chemical production, explosion protection is a duty of the operator, and inerting is the technical means of meeting it. It is also one of the things that decides how much nitrogen a site needs.

The Limiting Oxygen Concentration Decides, Not the Data Sheet

Below a substance-specific oxygen concentration a mixture can no longer ignite, and operating practice keeps a safety margin below that point. The figure differs widely between solvents, gases and dusts, so there is no universal number to quote. It comes from the safety data for the substance and from your own risk assessment.

In Germany, Section 12 of the Hazardous Substances Ordinance (GefStoffV) sets the order in which protective measures apply. First avoid hazardous quantities or concentrations of hazardous substances, then avoid ignition sources and triggering conditions, and only then reduce the harmful effects. Inerting puts the first step of that order into practice. The regulation does not use that word; the connection follows from the order of measures itself.

Oxygen Monitoring, Because Nitrogen Displaces Oxygen

Nitrogen is neither flammable nor toxic, and that is exactly why its real hazard gets underestimated. It displaces oxygen. Plant rooms need oxygen monitoring, and confined spaces need it all the more, so vessel entry follows the rules for work in confined spaces. The recognised industry reference is EIGA Doc 44, “Hazards of inert gases and oxygen depletion”.

The duties rest with the operator. The generator supplies the inert gas that meets them, and the sizing settles what volume and what purity arrive at the point of use.

That raises a question which belongs before the model choice rather than after it. Where inerting carries a protective measure, the availability of the nitrogen source sits in the same risk assessment as the measure itself. The buffer vessel bridges minutes, not hours. What fallback is needed beyond that, and whether the process needs one at all, depends on your substances and your operating mode, and that decision belongs in the plant design before a machine is selected.

On-Site Generation or Bulk Liquid Supply for Chemical Plants

The conventional route is liquid nitrogen delivered in bulk, or cylinder bundles. Both come with a supply contract, annual price adjustments and delivery dates. Where demand is small, uneven or only occasionally high, delivery remains the right answer. Where the load is high and sustained, as it usually is in chemical manufacturing, the calculation turns towards on-site generation. The sizing shows where that line falls for your annual quantity and load profile. What you trade is one price risk for another: instead of your gas supplier’s annual adjustment you carry the electricity price. You buy electricity anyway, you know your terms, and you are not tied to a single supplier under a take-or-pay obligation.

The Gas Invoice Becomes a Line You Can Calculate

The recurring gas invoice turns into an investment and into an electricity cost you can calculate. Under a high, steady load, payback against bulk liquid nitrogen supply is typically two to three years. The comparison is on-site generation against an ongoing bulk liquid supply; an extension of your compressed air station is not inside that span and belongs in your own calculation. A tank also loses product to boil-off whether you draw from it or not.

Wear Parts in Time for Your Shutdown

Filters and standard components can be bought anywhere on the open market. That matters less for the price than for the date: parts every distributor stocks arrive inside your maintenance window, instead of waiting on one supplier to ship them.

Volume Without a Supply Contract

The volume available depends on the compressor and on your own demand, not on an offtake agreement and not on a delivery slot. If your load profile changes, you change how the plant runs instead of renegotiating terms afterwards.

Direct Access to Engineering

Sizing questions go to engineering rather than to a call centre, reachable on +49 2151 568 9550. Delivery, commissioning, operator training and service come from one source within the BERG Group, and warranty runs three years as standard, up to five with a service contract.

Matching Nitrogen Generator Size to Your Flow Rate

500 and 4000 are model designations, not output figures. Eighteen model sizes sit between those two ends, covering 4.1 to 654.9 Nm³/h at 99.9 % purity, so the gaps between them are small. Usable output depends on the purity you set, which is why the table gives the span per purity instead of a single figure.

ParameterModel 500Model 4000
Nitrogen at 97 %10.7 Nm³/h1,709.1 Nm³/h
Nitrogen at 99.9 %4.1 Nm³/h654.9 Nm³/h
Nitrogen at 99.999 %1.2 Nm³/h191.7 Nm³/h
Compressed air demand at 99.9 %13.9 Nm³/h2,226.6 Nm³/h
Nitrogen vessel90 l6,000 l
Air receiver90 l10,000 l

For most chemical sites the operating point is 99.9 %. High purities cost usable output, compressed air and therefore a larger machine: at 99.999 % the same machine delivers roughly a ninth of what it delivers at 97 %. For the complete system with compressor, air treatment and storage, the nitrogen generation package page takes it from there, and the product overview puts the range in context.

Common Questions from Chemical Plants

Your Load List Becomes a Sizing Proposal

Send the quantities, purities and timing of your points of use. You get back a sizing with model, compressed air demand and buffer volume, together with a quote.

Send Your Load List