PHARMA

Nitrogen Generators for the Pharmaceutical Industry

In the manufacture of medicines, nitrogen is what keeps oxygen away from the product: in the reactor, during transfer and drying, in the freeze dryer and in the pack. NITROBERG® generators produce that gas on your own site from compressed air, at grades from 97 % up to 99.999 %. This page works through what your processes actually need in purity, volume and continuity, before a model gets chosen.

97 % to 99.999 %Nitrogen purity configured to the process
10 ppmResidual oxygen at quality grade 5.0
1.2 to 1,709.1 Nm³/hNitrogen output across the NITROBERG® range
PED 2014/68/EUConformity assessed, notified body NB 2912
Send us your process list and consumption profile for a sizing proposal
High N₂ PurityUp to 99.999 % at the point of use
Cut Recurring CostsPredictable kWh-based OPEX
Made in GermanyEngineering and manufacturing
Worldwide ServiceBERG Kompressoren network

What nitrogen does in pharmaceutical production

Nitrogen in a pharmaceutical plant is a process gas. It displaces oxygen and moisture wherever their presence would change the product: as a blanket over solvents and oxygen sensitive intermediates, as an inert atmosphere in reactors and dryers, as the purge that clears vessels and lines after cleaning, as the carrier that moves powders without an explosive atmosphere forming, as the backfill in vials before stoppering, and as the headspace in blisters and bottles. Gases administered to patients belong to a separate regulatory category with its own requirements, and they are not what this page is about.

What makes the supply question harder here than in most industries is not the volume. It is that the consumers are unlike each other. A reactor inerting duty draws steadily for hours. A purge cycle draws hard for minutes and then stops. A packaging line draws a small, constant trickle. The QC laboratory draws almost nothing and sets the highest purity on the site.

A nitrogen generator answers that by making the gas on site from compressed air. In a PSA system, compressed air flows through a bed of carbon molecular sieve that holds back oxygen, carbon dioxide and residual moisture much faster than it holds back nitrogen. Two beds alternate, one producing while the other regenerates at lower pressure, so the supply does not pause between cycles. The PSA nitrogen generator page describes the process step by step, and the carbon molecular sieve article explains why that one component sets the ceiling on purity.

Nitrogen Generators for Pharmaceutical Industry

Which nitrogen purity each pharmaceutical process needs

Purity on a pharmaceutical site is usually specified once, for everything, by whoever happened to have the most demanding process. That is the most expensive way to do it. The grades below are the ones normally used in practice. Treat them as a starting point and confirm them against your own validated process parameters, because the requirement moves with the product, the vessel and the purge strategy.

ProcessTypical gradeWhat the nitrogen doesDrives
Reactor inerting, API synthesis99.9 % to 99.99 %Inert atmosphere over oxygen sensitive chemistryPurity
Solvent storage and handling99.9 %Blanket that holds the headspace below the limiting oxygen concentrationVolume
Purging vessels and lines after cleaning99.9 %Removes residual air and moisture before the next batchVolume
Drying and powder transfer99.9 %Carrier and drying gas without an oxidising atmosphereVolume
Lyophilisation, vial backfill before stoppering99.99 % and aboveInert headspace in the closed vialPurity
Blister, bottle and pouch headspace99.9 % to 99.99 %Displaces oxygen at the point of sealingVolume
QC laboratory instrumentsup to 99.999 %Carrier, collision and evaporation gasPurity

Read the table by column rather than by row. The volume comes from blanketing, purging and packaging, which run constantly and are cheap to supply. The purity comes from one or two processes that will happily set the grade for the whole site if nobody separates them. Where a requirement is written as residual oxygen in the vessel rather than as a gas grade, the purge strategy carries as much weight as the gas itself: it is the number of exchanges that gets you to the ppm figure, not the label on the generator.

What higher purity costs you in compressed air

Every NITROBERG® size consumes a defined amount of compressed air per cubic metre of nitrogen it delivers. That ratio, the air factor, is the same across the range and depends only on the purity you set.

Purity97 %98 %99 %99.5 %99.9 %99.99 %99.995 %99.999 %
Air factor2.32.32.62.93.44.65.26.4

Put a plant figure into it. A site drawing 60 Nm³/h for blanketing and purging needs around 204 Nm³/h of compressed air at 99.9 %. Specify 99.999 % across the site instead and the same 60 Nm³/h needs around 384 Nm³/h: close to twice the compressor, twice the electricity and twice the compressor room, for gas quality that blanketing cannot use. That is the whole argument for splitting the supply. Analytical instruments and vial backfill on a high purity line, blanketing and purging on their own cheaper one, each sized for what it does. The energy consumption article works through the running cost side of that decision.

How to size a nitrogen generator for a pharmaceutical plant

1

List the consumers, not the plant

Take a figure per consumer: reactor, dryer, packaging line, transfer system, laboratory. Then separate the ones that draw continuously from the ones that draw in bursts. A purge cycle is a peak, not a running load, and a system sized on the sum of all peaks is a system nobody needed.

2

Set the purity from the process, not from the site

Take the most demanding requirement on the list, then ask whether it belongs on the same supply as everything else. Where the specification is written as residual oxygen in the vessel, confirm what that means for the gas grade before it turns into a site wide number.

3

Decide the buffer and reserve concept

A batch that cannot be interrupted changes the sizing before any model is chosen. The nitrogen vessel carries a buffer, and how large it has to be follows from the longest interruption your process can absorb. The reserve supply strategy is defined together with the system design and the requirements that apply at your site.

4

Check the compressed air, quantity and quality

Flow times air factor gives the demand. Quality counts as much as volume and is the part that gets forgotten: oil carry-over and residual moisture shorten the life of the carbon molecular sieve, so an undersized dryer costs more over five years than a slightly undersized compressor. NITROBERG® expects compressed air to ISO 8573-1:2010 Class 1.4.1 at 7 bar(g).

Need sizing for your application?

You do not need a full data set to start. Tell us roughly what you use today and we will say whether on-site generation is worth a closer look for your operation. If you already have flow, purity and operating hours to hand, send them and you get a sizing proposal back.

Documenting nitrogen quality in a GMP environment

With delivered gas, quality arrives as a certificate attached to a delivery, and the record behind it belongs to somebody else. With on-site generation the record is yours, and it is continuous rather than per delivery. Residual oxygen in the product stream is measured while the plant runs, so a drift shows up as an alarm during the batch instead of as a question afterwards. Most operators find that the stronger position. It does, however, move work forward into the design stage.

That work is worth naming, because none of it is answered by a generator specification. Where do the sampling and measuring points sit, and are they at the point of use or only at the generator? What is monitored continuously, and what is checked periodically? How is the pipework routed so that dead legs and low points do not undo what the generator delivers? What has to be qualified, and what documentation does that qualification need? Verifying gas quality at the point of use is the operator’s responsibility, and every one of these questions is cheaper to settle before the pipework goes in than after. Bring the documentation requirement into the sizing conversation and the measuring points can be designed in from the start.

On-site nitrogen compared with cylinders and bulk liquid supply

Cylinders and a bulk liquid tank both deliver purity, and both charge for time rather than for gas. Rental runs through quiet weeks, evaporation losses run overnight, contracts carry price escalation clauses, cylinder handling ties up people in a building where clean space is expensive, and the delivery schedule that decides when the tank is full is not one you control. On-site generation replaces that with an investment and an electricity bill. For many of the plants we have supplied, the payback against liquid-gas supply has fallen within two to three years. Whether it does for you depends on your consumption profile and your electricity price, so that calculation is worth running together rather than taking a rule of thumb.

Purity you configure and monitor

The generator is set to the grade your processes need rather than to the highest one available, and residual oxygen is measured continuously in the gas it delivers. A drift shows up as an alarm, not on a certificate that arrives with the next delivery.

Standard wear parts

Filters and consumables are off-the-shelf items from the open market. There is no proprietary parts programme waiting after the purchase, and it is worth asking every supplier you compare where their filters come from.

Capacity that follows the site

The NITROBERG® range runs from 1.2 to 1,709.1 Nm³/h across 18 sizes, so the same technology covers a single packaging line, a filling suite and a full production building. Capacity is added as lines are added.

Direct access to engineering

Sizing and documentation questions go to the people who design the machines, not to a call centre. Delivery, commissioning and service come from one source within the BERG Group. Warranty runs three years as standard and up to five years with a service contract.

NITROBERG® sizes for pharmaceutical duty

The sizes below cover the band most pharmaceutical installations fall into, shown at the three grades that matter here. Smaller duties sit further down the range: the NITROBERG® 500 delivers 1.2 Nm³/h at 99.999 %, which is enough for a single filling line or a laboratory bench.

ModelN₂ at 99.9 %N₂ at 99.99 %N₂ at 99.999 %
NITROBERG® 100034.4 Nm³/h18.5 Nm³/h10.1 Nm³/h
NITROBERG® 110045.1 Nm³/h24.2 Nm³/h13.2 Nm³/h
NITROBERG® 120055.8 Nm³/h29.9 Nm³/h16.3 Nm³/h
NITROBERG® 130078.7 Nm³/h42.2 Nm³/h23.0 Nm³/h
NITROBERG® 1400109.9 Nm³/h59.0 Nm³/h32.2 Nm³/h

Note what the columns do to each other. The machine that delivers 55.8 Nm³/h at 99.9 % delivers 16.3 Nm³/h at grade 5.0. Specify a whole site at the grade one instrument needs and you buy three machines where one would have done. Above these sizes the range continues to 1,709.1 Nm³/h, which is the territory of a site supplying several buildings from one source. Applicable NITROBERG® pressure equipment is conformity assessed under PED 2014/68/EU within the certified scope. Engineering and manufacturing are Made in Germany.

Where a site has no suitable compressed air network, the nitrogen generation package combines generator, air generation, treatment, storage and control in one pre-assembled unit, in plug-and-play configurations for NITROBERG® 500 to 900. Pharmaceutical nitrogen is one of several application areas that share this technology: instrument supply in the QC laboratory is covered on the laboratory page, and intermediate and fine chemical production on the chemical applications page.

FAQ: nitrogen generators for pharmaceutical manufacturing

Need sizing for your application.

Start with a conversation. Tell us what you run today and we will tell you what is realistic for your operation. When you are ready for numbers, send flow, purity and operating profile and you get a sizing proposal and a quote.

Talk to us about your nitrogen supply